ACUAVED Special coating for casting on Chrome-Cobalt.
The coating contains quartz powder.
Do not inhale this powder!
The Acuavest® coating is designed to be used with water.
The expansion liquid expansor expansion is appropriate when making the employer. Do not use crystallized exploring liquid!
- Duplicate model: for 200 g of powder, use the following mixture: 13-14 ml Expansor + 13-14 ml of distilled water.
- Cylinder: for 400 g of powder, use the following mixture: 55-60 ml of distilled water.
- In both cases, if the mixture of the coating is done manually, do it on a vibrator.
- Prepare the liquid according to the desired concentration, add the powder to the liquid and vigorously mix 60 s. Mechanical mixture under vacuum, for 30 s.
ACUAVE - working time 4 to 5 minutes at room temperature, powder, liquid and utensils at 20 - 22 ° C.
When liquids or gelatins are colder, the plug is extended.
- The filling of the models must be carried out on a vibrator.
- To guarantee smooth and hard surfaces, keep the vibrations for 2 minutes.
- Duplicate can be performed with gelatin or silicone.
- Taking time: 30-35 minutes, both for duplicate models and for cylinders.
- Dehydration of models 40 minutes in an oven at 220-240 ° C.
- We recommend the technodur hardener.
- With silicone duplication, this operation is not useful.
- Put the model of a fine coating or treat it with an extended agent.
- Fill the cylinder with a slight vibration. Demolage at 35 minutes.
Drying, after 35 minutes of socket, bake the models preferably in a cold oven and now at 240 ° C for 40 minutes.
- Once the cylinders are dry, program the flow temperature.
- The maximum recommended temperature is 900 ° C for partial prostheses and 1000 ° for total plates.
- Maintain this temperature for at least 45 minutes.
- The best expansion is obtained with a heating at the rate of 5 ° C/minute.
Once the maintenance period in the oven has passed, do the casting as usual.
- After the casting, wait until the Masselotte is redest.
- Once the cylinders are slightly cooled in the open air, immerse them completely in the water.
- In this way, demouflage becomes very easy.
ACUAVEST® powder Store at 18-25ºC Maintain well closed packaging away from humidity.
This coating is sensitive to humidity, prolonged exposure to air can alter the characteristics of the product.
- Expansor Store at 18-25ºC, prolonged exposure to a temperature below 5ºC or greater than 35ºC can cause freezing and/or destabilization of the product.
- Maintain well closed packaging after each use.
- Prolonged air exposure can cause crystallization.
Delivery : Cardboard 18 kg (45 x 400 gr) or cardboard 20 kg (10 x 2000 gr) or liquid.